本文へスキップします。

【全・英】メガメニュー
H1

Ultrasonic Flowmeter UW-10

製品詳細

Ultrasonic Flowmeter

Ultrasonic Flowmeter UW-10 Now Comes, No pressure-lose ! Small & Lightweight !
High accuracy !
The UW-10 boasts +/- 1% high accuracy readings in a compact configuration, half the size of our former model.
TOKYO KEIKI was the first company in the world to develop an ultrasonic flowmeter for general industry in 1963. In 2022, we completed development of a highly reliable ultrasonic flowmeter - the "UW Series" - using our wealth of accumulated know-how and the latest in hardware technology.

Engineering Specifications[doc]

▼ Document Download

uw-10_2401_e.pdf

pds_uw10_202309.pdf Product data sheets

operation_manual_uw_10_kf21_003c.pdf Operation Manual

Engineering Specifications[doc]

eu_declaration_uw-10_cset-22-019.pdf EU Declaration[PDF]

The UW-10 features clamp-on mounting which enables non-intrusive, no pressure loss installation on existing or new pipes. Ultrasound technology enables measurement of a variety of fluids regardless of electro-conductance. 

The UW-10 Series is a 6th generation system which offers higher accuracies and a wealth of functions.
 
  • Measures disordered velocity distribution
  • Multi-function
  • Easy operation
  • Abundant experience in various applications


Specifications

  Fluids  Homogeneous and sonically conductive fluids
 (water, waste water, industrial water, river water, seawater, purewater, etc.) 
Temperature range  -25℃ to +65℃ (depend on transducer)

Note:
1) above also applicable to ambient temperature
2) For main unit, -10℃ to +60℃
Turbidity 10000 mg/L or less
Pipes Material Materials which allow stable transit of ultrasonic waves such as Carbon steel, Stainless steel, SUS, Castings, Ductile casting, PVC, FRPM, GRP, HDPE, PE, etc.

Note: Applicable diameters may vary with material.
Diameters DN25mm to DN6000mm
Lining None, tar epoxy, mortar, etc.
Measurement Range Converted to flow velocity -30 m/s to +30 m/s
Measurement Cycle 60 ms
Measurement Accuracy D≧300mm, ±1% of reading, however ±0.008m/s for velocities less than 0.8m/s.
D<300mm, ±1% of reading, however ±0.02m/s for velocities less than 2m/s.

Note:
1) For volumetric flow rate.
2) Fully developed and rotationally symmetrical flow profile required.
3) Calibrated accuracy defined on project specification as Option.
Repeatability ±0.5% of reading
Note : 1) According to our standard.
Note : 2) Velocity 0.5 m/s
Range ability 1:300
Measurement Method Ultrasonic pulse transit time difference method 